Standard and not very sizes of doorways of interior doors. Standard sizes of doorways Internal doors of residential buildings

When overhauling or building, everything must be taken into account - even the width and height of the doors. Dimensions doorways, of course, can be arbitrary, but then you will always have to make doors to order. It's easier to comply with the standards - less costs and problems. Standard sizes interior doors registered in GOST. Let it be old, but most of it is built on them.

Standard sizes of doorways

On the territory of the Russian Federation, there is still a standard from the times of the USSR, which describes the requirements and dimensions of doorways, interior doors. There are a lot of TU and DSTU, but they have nothing to do with standards - each manufacturer writes them for himself. You can buy doors made according to technical conditions if their quality is at their best. But doorways should be made exactly standard dimensions.

Why is it better to make them according to the standard? Because then there will be no problems with the replacement. Almost all manufacturers make doors in accordance with GOST. After all, high-rise buildings are being built taking into account all the requirements (or they should be built that way). If the opening has special dimensions, the doors will only have to be ordered. And these are high costs, and there is no guarantee that you will like the finished product.

Dimensions according to GOST

So, even with a major overhaul or building your own home, during the construction interior partitions in a new building - in any case, we lay standard doorways. GOST provides for the following parameters:

  • Width:
    • Single leaf 700 - 900 mm (in 100 mm increments) and 1200 mm. In such doorways, it is recommended to install doors with single-leaf canvases.
    • Under double-leaf (the term double-field canvases are used in the standard), openings are made with a width of 1300 mm, 1500 mm and 1900 mm.
  • The standard height of the doorway can only be in two versions: 2100 mm and 2300 mm. Minimum allowable height- 2071 mm and 2271 mm, respectively.

These are the dimensions of standard doorways. No others. As for tolerances, the doorway can be narrower than the standard by 20-25 mm. In this case, it will also be possible to install the standard door block. Only the mounting gap will be smaller, which will not facilitate the work. That is, the narrowest doorway can be 675 mm (instead of 700 mm). According to the same principle, the tolerance can be calculated with respect to each standard width. It can be slightly reduced, but not more than 25 mm.

What to do if the actual dimensions do not meet the standard

What to do if a few millimeters are not enough to meet the standard? Depends on the material of the walls, as well as on the actual width of the passage. If the walls are machined, you can remove a few missing millimeters. Chop, grind, cut down. An ax, a chisel, a chisel, a grinder with a disc for concrete / brick, etc. Usually a couple of protrusions or curvature in some area interferes. If you align it, you can get closer to the desired size.

If the walls are made of very strong material, the only way to fit the opening to the standard is to reduce it to the next standard value. There are two ways: lay bricks, pieces of building blocks, plaster. The second option is to install a mortgage beam (treated with an antiseptic and dried), which, again, is covered with plaster, aligning it with the walls. In general, you understand the idea: it is more practical to bring non-standard dimensions to the standard.

Convenient sizes of interior doors

The height of the doorways is easier to determine. Everything is tied up at the height of the ceiling. Yes, and the choice is small - only two options - 2.1 m and 2.3 m. But what about the width? There are more opportunities here. In general, there are certain recommendations that relate to the minimum dimensions of doors. It is the doors, not the openings for them. The opening should be 70-100 mm wider. So, the dimensions of interior doors should be no less than the specified width:

  • In technical rooms (pantries, bathrooms, baths and toilets), the recommended web width is 600 mm.
  • For kitchens, the minimum is 700 mm.
  • For living rooms, at least 800 mm is recommended.

Of course, you can increase the size of interior doors if the doorway allows. Reduce - at your discretion. But the narrowest door leaf that can be found on sale is 550 cm, and even then it is inconvenient for obese people with it. In the kitchen and room where you can stand gas equipment, the width of doorways is dictated and controlled by the fire department. So it can no longer be done. Wider possible.

As for residential premises, openings can also be made in them for double doors. That is, up to the maximum permitted in GOST 1.5 meters. There may be wider ones, but this is already non-standard. In a wide opening, you can install not only conventional swing models, but also or. But large and wide doors look good in large areas. So the recommended sizes of interior doors are chosen for a reason. They took into account not too large rooms in our homes.

How to determine how wide the door leaf should be installed

If the doors are just going to be replaced, the easiest way is to measure the canvas that is already standing. So you definitely can't go wrong. If you will be installing doors for the first time, you need to measure the doorway and choose an option under it that will require minimal effort during installation.

How to measure a doorway

To choose the right size for a door or door unit, you need to know the exact dimensions of the opening in which they will be installed. Measurements are carried out using a conventional construction tape measure. Any parameter is measured at least at two points. If the difference is visually visible, you can measure more times, adjusting the position of the tape measure at your discretion.

The height of the doorway is measured at one and the other jamb, the width - at the top and bottom, approximately at a distance of 30-50 cm from the floor and the lintel. You can take measurements in the middle of the height. You also need to measure the thickness of the opening (wall thickness). It must be checked at least at two points on each side.

All measurements are recorded. It is better to do this on the doorway diagram. If there are deviations, we look at how serious the situation is and whether it can be corrected. If the bottleneck corresponds to the smallest possible standard opening, you can leave everything as it is. Otherwise, it will be necessary to try to correct the situation. It has already been described above.

But size isn't everything. It is necessary to check whether there are deviations in geometry. The side walls of the doorways should be vertical, and the lintel - horizontal. You can check the correctness of the form using the usual building level(bubble), but more convenient and more accurate using . You can check the side walls with a regular construction plumb line. If the deviations are large, they must be corrected. If their value is within a centimeter, it will be possible to compensate during installation using mounting plates and construction foam.

We select the sizes of interior doors and blocks

As already mentioned, the dimensions of interior doors are determined based on the dimensions of the existing opening. Doors are sold as a block complete with a box or only one leaf. It is more convenient to take the block - this speeds up installation. But buying a separate canvas and assembling a box will be cheaper. Here you choose either to pay less, but spend time and make extra efforts, or save time, but spend more money.

If you decide to buy a door block, make sure that its width (according to external dimensions door frame) was slightly less than the width of the opening. The minimum mounting gap is 10-15 mm, the optimal one is 25-35 mm.

When buying only a door leaf, it is assumed that it should be 80-100 mm narrower than the opening. It will be necessary to add two more jambs, and this is at least twice 25 mm each, plus a mounting gap of 10-15 mm, plus a gap on the sides of the door leaf - 5 mm. Total we get: 25 * 2 + 15 + 5 = 70 mm. This is the minimum value that must be added to the width of the door. The resulting figure must be equal to or less than the width of the doorway in which it will be installed.

Entrance door dimensions

Opening dimensions entrance doors also normalized. They are described in GOST 6629-88. If you want to install standard products, make openings according to the recommendations. If you are building your house, it is better not to lay the entrance doors less than the minimum width. And it's not just the difficulty of finding the right dimensions for the canvas. The fact is that there is a very high probability that the fire or gas service will force you to redo it.

Firms have their own standards for technical specifications

So, the standard dimensions of the entrance doors can be:

  • web width
    • for single-leaf - 900 mm, 1100 mm;
    • for double doors - 1400 mm (700 mm + 700 mm); 1800 mm (900 mm +900 mm).
  • canvas height - 2300 mm.

If we talk about what is on sale, then there are any doors. Moreover, you can order - iron or wood of any thickness. But again, this is non-standard. Although, the entrances are changed much less often than the interior ones.

A few words about what should be the doorway under the front doors. According to the same standard, it should be 70 mm wider than the leaf for single leaf doors and 72 mm wider for double leaf doors. These are the minimum values. A wider opening is possible, less is not. The height of the doorway for installing the front door should be 71 mm larger. That is, under the front door with a leaf 900 mm wide, you need an opening of at least 970 * 2371 mm. With the rest it is similar.

doorways - required elements any room, and their size depends on how convenient it is to enter the room, move large objects. With a few exceptions, the premises also have window openings, the dimensions of which should ensure required level natural light and access to fresh air. The dimensions of doors and doorways, as well as windows, are regulated by standards (GOST), as well as building codes and regulations (SNiP).

This avoids confusion in the design and construction to create normal conditions for the operation of residential, industrial and public buildings and structures. The size of the doorway is selected based on the convenience of the passage of people, as well as in accordance with the intensity of movement inside and outside the room. There are criteria by which typical sizes of windows are determined.

Dimensions of openings for interior doors and standard doorway of the front door

Speaking of standard doorway the size of the door leaf must also be taken into account. These are interrelated parameters that affect the convenience of entering and exiting the premises. In accordance with GOST 6629-80, the width of the opening is taken from 670 to 1872 mm, and the width of the door leaf from 600 to 1802 mm. At the same time, blind doors have a slightly smaller width than glazed ones. The height of the openings can be 2071 and 2371 mm, and for the canvas this value is 2000 and 2300 mm, respectively.

There is a dependence that is taken into account when choosing conventional hinged doors. First, the final dimensions of the opening under the door are determined, the dimensions of which are 70-80 mm larger than the canvas. Based on this ratio, the door is selected. The height and width of interior doors, in accordance with existing standards and requirements, is less than the entrance doors. This is due to the need to provide more free passage and carrying large items.

opening dimensions for sliding doors are regulated by the same standard, while the door leaf has slightly different dimensions. Unlike ordinary doors, sliding doors are 50-60 mm larger than the corresponding opening parameter. This is due to the fact that in this case the canvas moves parallel to the wall and must completely block the entrance to the room.

Standard dimensions of window openings: how is the width and height of the window opening determined?

At window openings dimensions are regulated by GOST 11214-86. This standard also determines the dimensions of balcony doors. In accordance with it, the width of the windows can be from 870 to 2670 mm, and the height from 1160 to 2060 mm. The value of these parameters is influenced by the area of ​​the room, the required level of illumination, as well as the architectural features of the building as a whole and the room in particular. As a rule, the area of ​​the window is chosen in proportion to the area of ​​the room, as well as the size of the whole house.

The size of the opening affects the window glazing scheme, the number of sashes and transoms. GOST 11214-86 also defines the dimensions of doors for access to a balcony or loggia. Balcony doors have a standard height of 2755 mm, but depending on the number of leaves and leaf features, they can be 870, 1170 and 1778 mm wide.

Windows are one of the important components that affect the architectural appearance of the building, and therefore they are chosen in such a way that they look organically and proportionately on its facades. Standard window dimensions are used for all standard solutions, although in individual projects it is allowed to use other sizes that allow highlighting the original architectural solution.

And a little more about GOSTs

What standard window sizes are used in residential buildings?

To date, standard window sizes are established by GOST 11214-86 and GOST 23166-99 "Wooden windows and balcony doors with double glazing for residential and public buildings." It clearly indicates technical requirements to structures, types, types, markings and standard sizes of windows and window openings in residential buildings. According to GOST, the standard size of windows is affected by the dimensions of the opening, the material from which the window is made, and its type. Therefore, standardization was carried out in all directions and norms for the size of the opening and windows were determined for a height of 60, 90, 120, 135, 150, 180 cm, and a width of 60, 90, 100, 120, 150, 180. For example, GOSTs offer such dimensions: 560x870 (opening 610x910); 560x1170 (opening 610x1210); 860x870; 860x1170; 860x1320; 860x1470; 1160x870(1170, 1320,1470); 1460x(1170, 1320,1470).

What door sizes can be used in residential areas?

GOST 6629-88 states that the minimum width of an internal blind door is 670 mm, while the leaf is 600 mm, and for a glass door it is 740 mm. As practice shows, this is not always enough for a comfortable stay. It is worth remembering that furniture may have to be brought in through the opening, and therefore it is advisable to increase the dimensions of the opening. Thus, for a bedroom and other living rooms, door sizes must be at least 90 cm, and the clearance must be at least 80 cm, and for a bathroom, door sizes according to GOST can be used.

Balcony Door Standards

The width of a standard balcony door depends on the type of building. For instance, standard width balcony door for constructions of the Khrushchev era was 680 mm. At the moment, there are no strict SNIPs (building codes and regulations) that establish certain minimum standards for a balcony door. Therefore, it is necessary to proceed from the technical possibilities. For example, the minimum leaf width of a plastic balcony door is 450 mm, but if you install such a structure, it will be problematic to pass through it. And therefore the best option an opening with a width of 610 mm is considered. The figure shows various options installation of a balcony door in residential premises.

The width of the window opening during design. What needs to be considered?

During the design of the future house, it is necessary to pay attention to the width of the window opening, its height, the geographical location of the house and the direction in which the window will go. First of all, the area of ​​the opening should provide normal light transmission of the window unit, sunlight should enter the room for 2.5 hours with continuous lighting, and the ratio of the area of ​​the room to the area of ​​the window should be at least 1:8. After the calculation of the area, it is necessary to choose the size of the opening. It is best to refer to GOST 11214-86 and use standard sizes for country houses, since non-standard values ​​will lead to additional costs and problems.

Standard sizes of windows in a panel house. How to take measurements?

Standard window sizes panel house have long been known. For example, if the house is of the P-49 series, then the typical dimensions of the window are 1310 by 1520 mm, if P-46, then 1470 by 1420 mm. But very often the builders made mistakes, and even in the same house the windows can differ in size from each other. That is why it is important to take accurate measurements. To do this, you will need a tape measure and a metal ruler. With a tape measure we measure the width and height of the window, and we stick the ruler down the slope and measure its depth. Thus, the sum of the width of the window and the depth of the slope on both sides is the width of the opening. After you need to check the diagonals, and if they are the same, you can start calculating the size of the window. As a rule, 2-4 cm are subtracted from the width of the opening. As for the height, we subtract 2 cm from the height of the window from above, and from the bottom, the height of the profile strip under the window sill.

How to choose the size of the front door?

In order to choose the right size of the front door, you need to know the size of the opening, after that you can use the tabular values ​​​​of the standard sizes of the door and the doorway and choose for yourself suitable option. If the size of the front door differs from the standard values, then you will have to use a double-leaf or half-leaf front door. It is also necessary to remember that a door that opens outward not only saves space in the hallway, but is also safer.

Dimensions of doorways. What needs to be remembered?

When choosing door and window openings, it is necessary to remember certain subtleties. First of all, I would like to note that it is best to design door and window sizes that meet the standards. There is a misconception that more is better. The larger the connector, the heavier the structure will be, and this becomes a problem, especially in a draft. Also very often the fittings fail. As for the window, the main thing here is not to overdo it, as huge windows in small rooms create a feeling of discomfort and insecurity. When calculating dimensions, do not forget to take into account the mounting gap and the material of the box, since the thickness depends on it.

More questions about your topic:

  • How to build a barbecue with your own hands from a brick for a summer residence, design and drawings of an outdoor brick barbecue, step by step construction, photo
  • Country toilet, arrangement and construction of a country toilet, optimal dimensions, drawings
  • Roofing screws for metal and wood, for flexible tiles and slate; galvanized roofing nails and T-shaped crutch

To properly install the door in the house, you first need to calculate its dimensions. It should be noted that the standard dimensions of doorways are clearly regulated by GOST and SNiP. This approach avoids confusion when designing private houses and multi-storey buildings. At the same time, the parameters of the entrance and interior canvases are selected based on the convenience and intensity of their operation.

Of course, when building a house, standards may not be adhered to, since they are more of a recommendation than a mandatory one. However, compliance with the approved dimensions has its advantages:

  1. Big choice. Almost all manufacturers produce door structures of standardized sizes. Therefore, you can easily choose best door for a specific case.
  2. Budget savings. Buying a non-standard canvas will cost you 30-50% more, because an individual order provides for additional labor costs in the manufacture of the product.
  3. Easy installation. The closer the size of the doorway to the standard, the easier it will be to seal the mounting seams.

Standard sizes of interior doors and openings

It is good if the openings for internal and entrance doors have standard sizes, since in this case installation work won't take a lot of your time and energy. If the place for installing the door frame is atypical, then you can get out of this situation in two ways:


  • make an individual order, significantly increasing the cost of the structure;
  • adjust the dimensions to the existing GOSTs.

In the second case, you will either need to expand the hole in the wall, which is not always possible due to the specific design of the apartment, or puzzle over how and how to close the doorway so that it is both reliable and attractive.

The dimensions of interior and entrance doors consist of two parameters: the dimensions of the opening and the door leaf itself. At the same time, the standards of domestic and foreign companies are different. Although these differences are small, they can significantly complicate the installation of doors. Most domestic companies in the production of single-leaf interior doors are guided by the following standards: leaf height - 200 or 230 cm, width - 80 or 90 cm, box thickness - 7.5 cm. In this case, the size of the opening in length and width should be 5-10 more cm, which is due to the presence of wooden or metal and assembly seams.

If the width of the opening is 110 cm or more, then it is recommended to make a double-leaf door, in which one part will be movable and the other deaf.

The standard width of such structures is (in cm):

  • 30+80;
  • 40+80;
  • 50+90;
  • 90+90.

Double-leaf products are often installed in offices, mansions and cottages. In terms of strength, they are in no way inferior to single-leaf, of course, if purchased from trusted manufacturers.

The dimensions of the door leaf also depend on where it will be installed:

  • for bathrooms in small apartments, doors 55 cm wide are usually used;
  • for kitchens - 70 cm;
  • for bedrooms and children's rooms - 80 or 90 cm.

Thickness interior design is no less important than the height and width, since the sound insulation and strength of the canvas directly depend on it. The thickness of the door can be as follows (in mm):

  • standard - 35-40;
  • hinged - 20-40;
  • from a wooden array with a sample of 1/4 - 35-45;
  • from pure wood - 45-55.

Entrance door dimensions

Such a concept as the standard size of the entrance opening is losing its relevance every year. This is especially true for private houses, in the construction of which standardization is increasingly receding into the background.

  • if an ordinary wooden product is mounted, then the dimensions will be 204x82.5 cm;
  • for metal structures- 205x86 (96) cm;
  • for double-leaf products - 200 (205) x160 cm.

How to calculate the dimensions of the doors yourself?

Before you go to the store and buy an entrance or interior door, you need to calculate its dimensions: width, height and thickness. If you have a doorway, then everything is quite simple. To calculate the width of the future canvas, you first need to measure the width of the opening at least at three points (bottom, middle and top). After that, assembly seams (10 mm on each side), the width of the loot and the gap between the canvas itself and the jamb (about 5 mm) are subtracted from the smallest value. The height of the doorway is considered similarly.


To calculate the thickness of the box, you will need to measure the thickness of the wall at three points, and then choose the largest value from the results obtained.

Today, almost all firms involved in the production of entrance and interior doors are trying to standardize the dimensions of their products in accordance with established standards. This must be taken into account when building a private house, since a properly planned building will allow you to install standard canvases, thereby saving a significant amount of money on an individual order.

Appendix 4

2.2, appendix 4

Appendix 4

2.2, 2.11, appendix 5

Appendix 6

______________
* Within the territory of Russian Federation the document is not valid. Valid GOST 19111-2001

5. RE-ISSUE

This standard applies to wooden internal doors for residential and public buildings, as well as for administrative and auxiliary buildings and premises of enterprises in various sectors of the national economy.

The standard does not apply to doors special purpose(including fire and soundproof) and doors made of fine wood.

1. TYPES

1.1. Doors, depending on the design, are divided into types:

G - with deaf canvases;

O - with glazed canvases;

K - with glazed swinging canvases;

U - with a continuous filler of cloths strengthened for entrances to apartments.

1.2. Doors of G and O types are made with one- and two-leaf leaves, with small-hollow (lattice) filling of the leaves, with and without a threshold, with and without overlap, with and without lining, with and without boxes.

Type K doors are made with double-leaf leaves, with small-hollow filling of the leaves, without a threshold, without a lap, with or without lining, with boxes.

Type U doors are made with single-leaf blind leafs, with a threshold, without overlap, without facings, with reinforced frames or without frames.

1.3. Doors are classified as products of normal moisture resistance.

1.4. The overall dimensions of the doors must correspond to those indicated in Fig. 1. The dimensions in the drawings of the standard are given for unpainted products and parts in millimeters. Dimensions of door openings are given in Appendix 1.

Damn.1. Door dimensions

Door dimensions

Damn.1

Notes:

1. Door schemes are shown from the opening side of the leaf.

2. The numbers above the door schemes indicate the dimensions of the openings in decimeters.

3. Dimensions in parentheses are for swing doors.


At the request of the consumer, it is allowed to manufacture doors of types O and K with sizes 24-12, 24-15, 24-19, as well as doors of type G with sizes 24-15, 24-19 with a height of 2071 mm.

It is allowed to manufacture double-leaf doors of types G and O with canvases unequal in width.

1.5. The following structure of the symbol (brand) of doors is established:

Legend Examples

Glazed single-leaf door for an opening with a height of 21 and a width of 10 dm, right, with a threshold:

DO21-10P GOST 6629-88

The same, deaf two-field for an opening 24 dm high and 15 dm wide, left, with a threshold:

DG24-15LP GOST 6629-88

The same, with swinging canvases for an opening with a height of 24 and a width of 19 dm:

DK24-19 GOST 6629-88

The same, reinforced, with a continuous filling of the canvas, for an opening 21 dm high and 9 dm wide, right:

DU21-9 GOST 6629-88

The leaf of a frameless door of type G, single-leaf for an opening with a height of 20 and a width of 7 dm, left, with a lap:

PG20-7LN GOST 6629-88

2. CONSTRUCTION

2.1. Doors must be manufactured in accordance with the requirements of GOST 475 and this standard according to working drawings approved in the prescribed manner.

2.2. The design, shape and dimensions of the doors must correspond to those indicated in Fig. 2, and the dimensions of the sections - in Fig. 3.

Damn.2. Design, shape and sizes of doors

Design, shape and sizes of doors

Drawing 2 (sheet 1)

Drawing 2 (sheet 2)

Drawing 2 (sheet 3)

Notes:

1. Sections of parts, see drawing 3.

2. It is allowed to manufacture doors of type U with overall dimensions type G doors

Damn.3. Types O and G

Types O and G

1 - mounting board; 2 - patterned glass according to GOST 5533 or reinforced glass according to GOST 7481, or window glass according to GOST 111 * 4-5 mm thick

Drawing 3 (sheet 1)

______________
GOST R 54170-2010, hereinafter in the text. - Database manufacturer's note.

Notes:

1. Sections of blind doors are similar to glazed ones, with the exception of glazing parts.

2. It is allowed to use plastic layouts for fixing glasses.

3. It is allowed to use mounting boards of a different design.

1 - shield frame bars; 2 - lining

Drawing 3 (sheet 2)

Note. The width of a double-leaf door with an average rebate without a rebate is 12 mm less than that indicated in drawings 1 and 2.

______________
* The document is not valid on the territory of the Russian Federation. GOST 5088-2005 is in force, hereinafter in the text. - Database manufacturer's note.

Drawing 3 (sheet 3)

1 - sealing gasket according to GOST 10174; 2 - cladding with fiberboard grade ST or T, group A, 3.2-5 mm thick according to GOST 4598 or waterproof plywood grade FK, 4-6 mm thick, according to GOST 3916.1 or GOST 3916.2

Drawing 3 (sheet 4)

Note. It is allowed to manufacture type U doors with a frame width of 74 mm for interior doors and doors of public buildings.

2.3. Door leafs of type Y must be manufactured with a continuous filling of the shield with calibrated thickness wooden slats or chipboard, as well as using width-calibrated chipboard strips laid on edge.

Examples of filling shields door panels are given in Appendix 2.

2.4. The vertical bars of the U-type door leaf frame must have a width of at least 90 mm. It is allowed to cut the bars along the length on both sides. The depth of the slots is 5-6 mm, the width is 3-4 mm.

It is allowed to use bars with a width of 45-60 mm, glued along the side surface.

Horizontal bars of the frame must have a width of at least 45 mm and be connected in the corners with vertical bars with glue in a spike or on dowels, staples, paper clips.

2.5. Doors are lined with materials in accordance with GOST 475 in the part related to doors of normal moisture resistance.

2.6. Doors used to complete sanitary cabins are allowed to be manufactured with a leaf 30 mm thick and at least 1800 mm high, with a frame bar width of at least 50 mm.

2.7. Doors of types O and K are allowed to be manufactured with a frame structure with a width of frame bars of at least 100 mm.

2.8. On the lower part of the doors of type U in public buildings, at the request of the consumer, strips of decorative paper laminate with a thickness of 1.3-2.5 mm according to GOST 9590 *, superhard fiberboard with a thickness of 3.2-4 mm according to GOST 4598, sheet aluminum are fixed on both sides or painted sheet steel. The width of the overlays is 220 mm.
________________
* The document is not valid on the territory of the Russian Federation (Order of Rostekhregulirovanie dated 06.04.2009 N 131-st). - Database manufacturer's note.

2.9. A box without a threshold is embroidered at the bottom with a mounting board fastened with nails or spiked joints to the ends of the vertical bars.

2.10. In doors of types O and K of public buildings, protective fences are installed on both sides, examples of which are given in Appendix 3.

2.11. Doors of type U and frameless doors of types G and O must be equipped with sealing gaskets in accordance with GOST 10174 or others that provide the necessary tightness of the porches.

2.12. The location of the devices is given in Appendix 4. Doors must be supplied with selected sockets for lock bodies (latches) and holes for handles.

Door leaves for frameless doors must be supplied with the top half-hinges installed, the bottom half-hinges must be packed and supplied as a set.

2.13. Installation options for frameless doors are given in Appendix 5.

Options for boxes with PVC lining for doors of types G, O without a threshold are given in Appendix 6.

Schemes for determining the left and right doors are given in Appendix 7.

The specification of glass for doors is given in Appendix 8.

2.14. The door purchase order must specify:

The number of doors by brand and the designation of this standard;

Type and color of finish;

Type and thickness of glass;

Instrument specification.

At the request of the consumer, it is allowed to supply door panels without boxes and boxes without panels.

APPENDIX 1 (informative). DIMENSIONS OF DOOR OPENINGS IN THE WALLS

ATTACHMENT 1
Reference

Note. The dimensions of openings for frameless doors are set taking into account Appendix 5.

1. Shield with solid filling wooden blocks(slats) or chipboard strips

2. Shield with small-hollow filling with wooden blocks (slats) or chipboard strips

3. Shield with small-hollow veneer filling

4. Shield with small-hollow filling made of plywood or hardboard

1 - spike, staple or paper clip; 2 - bars for installing a lock or handles; - clearance width, not more than 40 mm;
- clearance length, no more than 400 mm; - shift of rails relative to each other, not less than 50 mm

Drawing 5 (sheet 1)

5. Shield with small-hollow filling made of soft fiberboard

6. Shield with small-hollow filling made of solid fiberboard (option)

7. Board with small-hollow filling of paper honeycombs

8. Shield with small-hollow filling with wooden blocks (slats)

Drawing 5 (sheet 2)

Notes:

1. Example 1 - for a Y-type door, examples 2-7 - for a G-type door.

2. For a leaf with a height of 2300 mm, the length of the bars for installing the lock and handles is 700 mm. Installation of bars - see example 3.

3. When lining door panels of type G with fiberboard boards 3.2 mm thick, the width of the gap between the elements of small-hollow filling should not exceed 30 mm, and the length should not exceed 200 mm.

4. Filling the blind part of the glazed sheets can be performed by analogy with examples 3-7.

1 - wooden planks

Note. It is allowed to use plastic, metal and wooden fences of a different design.

1 - hinges PN1-110, PN1-85, PN2-110, PN2-85, PN3-110, PN4; 2 - handles RS100, RS140, RK1, RK2, locks and latches; 3 - gate valves ZT; 4 - hinges PV1-100, PV2-125 or screw and overhead hinges manufactured according to special specifications; 5 - locks ЗВ7А, ЗВ4; 6 - hinges PN1-130, PN1-150, PN2-130, PN3-130, PN3-150.

Notes:

1. Devices for doors must comply with GOST 5087, GOST 5088, GOST 5089 *, GOST 5090.
_______________
* The document is not valid on the territory of the Russian Federation. GOST 5089-2011 is valid. - Database manufacturer's note.

2. Types of devices for the doors of public buildings must be assigned in the projects of buildings.

3. Hinges PN9-130 are installed in swing doors according to GOST 5088.

APPENDIX 5 (informative). BOXLESS LEAF HINGE

APPENDIX 5
Reference

1 - wooden cork; 2 - steel plate; 3 - anchor; 4 - mortise loop; 5 - screw hinge card with a nut; 6 - sealing gasket according to GOST 10174

Drawing 8 (sheet 1)

1 - wooden cork; 2 - steel plate; 3 - anchor; 4 - overhead loop; 5 - sealing gasket according to GOST 10174; 6 - wooden threshold

Drawing 8 (sheet 2)

APPENDIX 6 (informative). PVC LINED BOXES

APPENDIX 6
Reference

Damn.9

Note. The vertical elements of the box are connected to the horizontal ones using spikes and steel dowels or screws.

APPENDIX 7 (informative). SCHEMES FOR IDENTIFYING LEFT AND RIGHT DOORS

APPENDIX 7
Reference

APPENDIX 8 (informative). GLASS SPECIFICATION FOR DOORS

APPENDIX 8
Reference

Door brand

Size, mm

Height

DO21-13, DK21-13

DO24-15, DK24-15

DO24-19, DK24-19

The text of the document is verified by:
official publication
wooden parts and
wood products for construction.
Part 1. Windows and doors: Sat. GOSTs. -
Moscow: IPK Standards Publishing House, 2002

GOST 6629-88

UDC 691.11.028.1:006.354 Group Zh32

STATE STANDARD OF THE UNION OF THE SSR

Wooden interior doors

for residential and public buildings

Types and design

Wooden inner doors for dwellings and public

buildings. Types and structures

OKP 53 6111, 53 6121

Introduction date 1989-01-01

INFORMATION DATA

1. DEVELOPED AND INTRODUCED by the State Committee for Civil Engineering and Architecture under the Gosstroy of the USSR

DEVELOPERS

Yu.A.Argo, Ph.D. tech. sciences (topic leader); I.V. Strokov; G.G. Kovalenko; Z.A. Burkova; I.I. Kiselev; N.P.Safonov, Ph.D. tech. sciences; V.T.Sokolova; T.S.Slastenko, Ph.D. tech. sciences; I.F. Savchenko; O.L. Bykovsky; N.D. Popkov; N.I. Zhukov; L.V. Voronkova; G.V. Levushkin; V.S. Ruchkin; N.B. Zhukovskaya; N.V. Shvedov

2. APPROVED AND INTRODUCED BY Decree of the State Construction Committee of the USSR dated December 31, 1987 No. 325

3. REPLACE GOST 6629-74

4. REFERENCE REGULATIONS AND TECHNICAL DOCUMENTS

The designation of the NTD to which the link is given

Item number, applications

GOST 111-90

2.2

GOST 475-78

2.1, 2.5

GOST 3916.1-89

2.2

GOST 3916.2-89

2.2

GOST 4598-86

2.2, 2.8

GOST 5087-80

Appendix 4

GOST 5088-94

2.2, appendix 4

GOST 5089-90

Appendix 4

GOST 5090-86

Appendix 4

GOST 5533-86

2.2

GOST 7481-78

2.2

GOST 9590-76

2.8

GOST 10174-90

2.2, 2.11

GOST 19111-77

Appendix 6

5. RE-ISSUE

This standard applies to wooden internal doors for residential and public buildings, as well as for administrative and auxiliary buildings and premises of enterprises in various sectors of the national economy.

The standard does not apply to special purpose doors (including fire and soundproof doors) and doors made of fine wood.

1. TYPES

1.1. Doors, depending on the design, are divided into types:

G - with deaf canvases;

O - with glazed canvases;

K - with glazed swinging canvases;

U - with a continuous filler of cloths strengthened for entrances to apartments.

1.2. Doors of G and O types are made with one- and two-leaf leaves, with small-hollow (lattice) filling of the leaves, with and without a threshold, with and without overlap, with and without lining, with and without boxes.

Type K doors are made with double-leaf leaves, with small-hollow filling of the leaves, without a threshold, without a lap, with or without lining, with boxes.

Type U doors are made with single-leaf blind leafs, with a threshold, without overlap, without facings, with reinforced frames or without frames.

1.3. Doors manufactured in accordance with this standard are referred to as doors of normal moisture resistance.

1.4. The overall dimensions of the doors must correspond to those indicated in Fig. 1. The dimensions in the drawings of the standard are given for unpainted products and parts in millimeters. Dimensions of door openings are given in Appendix 1.

At the request of the consumer, it is allowed to manufacture doors of types O and K with sizes 24-12, 24-15, 24-19, as well as doors of type G with sizes 24-15, 24-19 with a height of 2071 mm.

It is allowed to manufacture double-leaf doors of types G and O with canvases unequal in width.

1.5. The following structure of the symbol (brand) of doors is established:

Legend Examples

Glazed single-leaf door for an opening with a height of 21 and a width of 10 dm, right, with a threshold:

DO21-10P GOST 6629-88

The same, deaf two-field for an opening 24 dm high and 15 dm wide, left, with a threshold:

DG24-15LP GOST 6629-88

The same, with swinging canvases for an opening with a height of 24 and a width of 19 dm:

DK24-19 GOST 6629-88

The same, reinforced, with a continuous filling of the canvas, for an opening 21 dm high and 9 dm wide, right:

DU21-9 GOST 6629-88

The leaf of a frameless door of type G, single-leaf for an opening with a height of 20 and a width of 7 dm, left, with a lap:

PG20-7LN GOST 6629-88

2. CONSTRUCTION

2.1. Doors must be manufactured in accordance with the requirements of GOST 475 and this standard according to working drawings approved in the prescribed manner.

2.2. The design, shape and dimensions of the doors must correspond to those indicated in Fig. 2, and the dimensions of the sections - in Fig. 3.

2.3. Door leafs of type U must be made with a continuous filling of the shield with wooden laths or chipboard calibrated in thickness, as well as with the use of chipboard strips calibrated in width, laid on the edge.

Examples of filling the door leaf panels are given in Appendix 2.

2.4. The vertical bars of the U-type door leaf frame must have a width of at least 90 mm. It is allowed to cut the bars along the length on both sides. The depth of the slots is 5-6 mm, the width is 3-4 mm.

It is allowed to use bars with a width of 45-60 mm, glued along the side surface.

Horizontal bars of the frame must have a width of at least 45 mm and be connected in the corners with vertical ones with glue in a spike or on dowels, staples, braces.

2.5. Doors are lined with materials in accordance with GOST 475 in the part related to doors of normal moisture resistance.

2.6. Doors used to complete sanitary cabins are allowed to be manufactured with a leaf 30 mm thick and at least 1800 mm high, with a frame bar width of at least 50 mm.

2.7. Doors of types O and K are allowed to be manufactured with a frame structure with a width of frame bars of at least 100 mm.

2.8. On the lower part of the doors of type U in public buildings, at the request of the consumer, linings made of decorative paper laminate with a thickness of 1.3-2.5 mm according to GOST 9590, superhard fiberboard with a thickness of 3.2-4 mm according to GOST 4598, sheet aluminum or painted sheet steel. The width of the overlays is 220 mm.

2.9. A box without a threshold is embroidered at the bottom with a mounting board fastened with nails or spiked joints to the ends of the vertical bars.

2.10. In doors of types O and K of public buildings, protective fences are installed on both sides, examples of which are given in Appendix 3.

2.11. Doors of type U and frameless doors of types G and O must be equipped with sealing gaskets in accordance with GOST 10174 or others, providing the necessary tightness of the porches.

2.12. The location of the devices is given in Appendix 4. Doors must be supplied with selected sockets for lock bodies (latches) and holes for handles.

Door leaves for frameless doors must be supplied with the top half-hinges installed, the bottom half-hinges must be packed and supplied as a set.

2.13. Installation options for frameless doors are given in Appendix 5.

Options for boxes with PVC lining for doors of types G, O without a threshold are given in Appendix 6.

Schemes for determining the left and right doors are given in Appendix 7.

The specification of glass for doors is given in Appendix 8.

2.14. The door purchase order must specify:

The number of doors by brand and the designation of this standard;

Type and color of finish;

Type and thickness of glass;

Instrument specification.

At the request of the consumer, it is allowed to supply door panels without boxes and boxes without panels.

Door dimensions

Damn.1

Notes:

1. Door schemes are shown from the opening side of the leaf.

2. The numbers above the door schemes indicate the dimensions of the openings in decimeters.

3. Dimensions in parentheses are for swing doors.

Design, shape and sizes of doors

Drawing 2 (sheet 1)

Drawing 2 (sheet 2)

Note. Sections of parts, see drawing 3.

Drawing 2 (sheet 3)

Notes:

1. Sections of parts, see drawing 3.

2. It is allowed to manufacture doors of type Y with overall dimensions of doors of type G.

1 - mounting board; 2 - patterned glass according to GOST 5533 or reinforced glass according to GOST 7481, or window glass according to GOST 111 with a thickness of 4-5 mm

Drawing 3 (sheet 1)

Notes:

1. Sections of blind doors are similar to glazed ones, with the exception of glazing parts.

2. It is allowed to use plastic layouts for fixing glasses.

3. It is allowed to use mounting boards of a different design.

1 - shield frame bars; 2 - lining

Drawing 3 (sheet 2)

Note. The width of a double-leaf door with an average rebate without a rebate is 12 mm less than that indicated in drawings 1 and 2.

1 - loop PN9-130 according to GOST 5088; 2 - window glass according to GOST 111 with a thickness of 4-5 mm

Drawing 3 (sheet 3)

1 - sealed gasket according to GOST 10174; 2 - lining of fiberboard grade ST or T, group A, 3.2-5 mm thick according to GOST 4598 or plywood grade FK, 4-6 mm thick, according to GOST 3916.1 or GOST 3916.2

Drawing 3 (sheet 4)

Note. It is allowed to manufacture type U doors with a frame width of 74 mm for interior doors and doors of public buildings.

ATTACHMENT 1

Reference

DIMENSIONS OF DOOR OPENINGS IN THE WALLS

Damn.4

Note. The dimensions of openings for frameless doors are set taking into account Appendix 5.

APPENDIX 2

EXAMPLES OF FILLING SHIELD DOOR LEAF

1 - spike, staple or paper clip; 2 - bars for installing a lock or handles; h - clearance width, not more than 40 mm; l - clearance length, not more than 400 mm; b - shift of the rails relative to each other, not less than 50 mm

Heck. 5 (sheet 1)

Heck. 5 (sheet 2)

Notes:

1. Example 1 - for a Y-type door, examples 2-7 - for a G-type door.

2. For a leaf with a height of 2300 mm, the length of the bars for installing the lock and handles is 700 mm. Installation of bars - see example 3.

3. When lining door panels of type G with fiberboard boards 3.2 mm thick, the width of the gap between the elements of small-hollow filling should not exceed 30 mm, and the length should not exceed 200 mm.

4. Filling the blind part of the glazed sheets can be performed by analogy with examples 3-7.

APPENDIX 3

Examples of installation of protective fences

1 - wooden planks

Damn.6

Note. It is allowed to use plastic, metal and wooden fences of a different design.

APPENDIX 4

LOCATION OF INSTRUMENTS IN THE DOORS

1 - loops PN1-110, PN1-85, PN2-110, PN2-85, PN3-110, PN4; 2 handles PC100, PC140, RK1, RK2, locks and latches; 3 - gate valves ZT; 4 hinges PV1-100, PV2-125 or screw and overhead hinges; manufactured according to special specifications; 5 - locks ЗВ7А, ЗВ4; 6 - loops PN1-130, PN1-150, PN2-130, PN3-130, PN3-150.

Damn.7

Notes:

1. Devices for doors must comply with GOST 5087, GOST 5088, GOST 5089, GOST 5090.

2. Types of devices for the doors of public buildings must be assigned in the projects of buildings.

3. Hinges PN9-130 are installed in swing doors according to GOST 5088.

APPENDIX 5

Reference

BOXLESS LEAF HINGE

1 - wooden cork; 2 - steel plate; 3 - anchor; 4 mortise loop; 5 - screw hinge card with a nut; 6 - sealing gasket

Drawing 8 (sheet 1)

1 - wooden cork; 2 - steel plate; 3 - anchor; 4 patch loop; 5 - sealing gasket; 6 - wooden threshold

Drawing 8 (sheet 2)

APPENDIX 6

Reference

PVC LINED BOXES

Damn.9

Note. The vertical elements of the box are connected to the horizontal ones using spikes and steel dowels or screws.

APPENDIX 7

Reference

SCHEMES FOR IDENTIFYING LEFT AND RIGHT DOORS

Damn.10

APPENDIX 8

Reference

GLASS SPECIFICATION FOR DOORS

Size, mm

Door brand

Height

Width

Quantity

UP TO 21-8

1300

475

UP TO 21-9

1300

575

UP TO 21-10

1300

675

DO 21-13, DK 21-13

1300

375

UP TO 24-10

1600

675

UP TO 24-12

1600

875

DO 24-15, DK 24-15

1600

475

DO 24-19, DK 24-19

1600

675

Liked the article? Share it
Top